3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
  • 3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
S11 S13 S20 S22
Core
Core-type Transformer
Cooling Method
Oil-immersed Type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Sinm
Material
Aluminum or Copper
Warranty
2 Years
Trademark
Sinm
Production Capacity
5000pieces

Product Description

Product Description

On load tap changer transformer plays an important role in power system.It can not only stabilize the load center voltage, but also connect the power grid, adjust load current, improve reactive power distribution etc.Its basic principle is to lead out several taps from the coil on one side of the transformer, and switch from one tap to another through OLTC, without cutting off the load current.So as to change the effective number of turns and achieve the purpose of voltage regulation.


On load voltage regulation technology of transformer is widely used in distribution system, and also in step-up transformer of power plant. At present, almost all the large capacity transformers in the power system adopt on load voltage regulators,It is also equipped with a perfect low-voltage distribution network structure and sufficient reactive power compensation capacity to ensure  the safe operation of the power grid and meet the requirements of customers for power quality.

Product features
1.No load voltage regulating transformer need to adjust the tap of high-voltage side only when the power is cut off, 
so as to change the ratio of the transformer to regulate the voltage at the low-voltage side.Its regulation range is small, generally within ± 5%, It can only be adjusted once or twice a year.Most transformers in power system are no-load tap transformers.
2.The on load tap changing transformer has a special switch, which can change the tap position without power off (with load).Its voltage regulation range is large, generally more than 15% or even up to 30%, and it can be adjusted  automatically for several times a day.

3.No excitation voltage regulation refers to no-load voltage regulation,which can be adjusted only when the transformer is off.On load tap chaning transformer can change the voltage by changing the tap position when it is on running.

4.OLTC switch has the advantages of frequent on-off, no spark and long service life.The traditional trigger circuit of power electronic switch has the 
problem of electrical isolation.The application of optical fiber communication technology to the medium and high voltage trigger control system
 can effectively solve the problem of high and low voltage electrical isolation.
sz11 three phase oil immersed transformer series parameters
3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
Mechanical parameters
Rated capacity (kVA) H.V.  
 (kV)
Tapping range L.V.  (kV) Vector group Loss(kW) No-load current (%) Impedance voltage  (%) Weight (kg)
Load loss No-load loss oil Total
10 6,10,11        ±5%       or     ±2*2.5%  0.4   0.415 0.433 Dyn11 
        or         
Yyn0
0.26 0.09 3.2 4 45 172
20 0.44 0.10 3.0 65 240
30 0.63 0.13 2.3 65 245
50 0.91 0.17 2.0 80 330
63 1.09 0.20 1.9 90 365
80 1.31 0.25 1.9 95 410
100 1.58 0.29 1.8 115 490
125 1.89 0.34 1.7 140 620
160 2.31 0.40 1.6 155 720
200 2.73 0.48 1.5 175 810
250 3.20 0.56 1.4 200 940
315 3.85 0.67 1.4 215 1090
400 4.52 0.80 1.3 240 1250
500 5.41 0.96 1.2 285 1460
630 6.20 1.20 1.1 4.5 345 1720
800 7.50 1.40 1.1 390 2050
1000 10.30 1.70 1.0 460 2430
1250 12.00 1.95 1.0 550 2850
1600 14.50 2.40 0.8 690 3600
2000 18.00 2.60 0.7 790 4300
 
Rated capacity(kVA) H.V. (kV) Tapping range L.V. (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weight (kg)
Load loss No-load loss oil Total
30 15,20       ±5%               or          ±2*2.5% 0.4,0.415. 0.433 Dyn11 
         or           
Yyn0
0.60 0.10 2.1 4 85 350
50 0.87 0.13 2.0 90 480
63 1.04 0.15 1.9 110 600
80 1.25 0.18 1.8 110 660
100 1.50 0.20 1.6 120 700
125 1.80 0.24 1.5 130 800
160 2.20 0.29 1.4 140 940
200 2.60 0.33 1.2 160 1130
250 3.05 0.40 1.2 180 1290
315 3.65 0.48 1.1 230 1400
400 4.30 0.57 1.0 250 1550
500 5.15 0.68 1.0 260 1780
630 6.20 0.81 0.9 4.5 320 2100
800 7.50 0.98 0.8 350 2560
1000 10.30 1.15 0.7 450 2800
1250 12.00 1.36 0.6 490 3200
1600 14.50 1.64 0.6 640 4000
2000 17.14 1.94 0.6 800 4900
2500 20.26 2.30 0.5 1180 6300
 
Rated capacity(kVA) H.V.  (kV) Tapping range L.V.  (kV) Vector group Loss(kW) No-load current (%) Impedance voltage (%) Weightb (kg)
Load loss No-load loss oil Total
50 30,33,35 ,38.5        ±5%                or          ±2*2.5% 0.4   0.415 0.433    Dyn11   
    Yyn0     
Yd11
1.27 0.21 2.0 6.5 265 860
100 2.12 0.29 1.8 310 1150
125 2.50 0.34 1.7 320 1190
160 2.97 0.36 1.6 360 1230
200 3.50 0.43 1.5 390 1300
250 4.16 0.51 1.4 425 1480
315 5.01 0.61 1.4 460 1590
400 6.05 0.73 1.3 490 1760
500 7.28 0.86 1.2 540 2150
630 8.28 1.04 1.1 620 2380
800 9.90 1.23 1.0 780 2800
1000 12.15 1.44 1.0 850 3410
1250 14.67 1.76 0.9 950 3890
1600 17.55 2.12 0.8 1060 4620
2000 19.35 2.72 0.7 1195 5345
2500 20.70 3.20 0.6 1285 5960
3150 24.30 3.80 0.6 7 1470 6695
4000 28.80 4.52 0.5 1760 8350
 
Rated capacity(kVA) High voltage(kV) High voltage  tapping range(%) Low voltage(kV) Vector Group symbol No-load Loss
(kW)
On-load Loss
(kW)
No-load Loss
(kW)
On-load Loss
(kW)
Short-circuit resistance
(%)
No-load Current
(%)
Model 11 Model 18    
3150 35
38.5

 
±2 × 2.5
±3 × 2.5
±4 × 2.5
 
6.3
10.5
Yd11
 
3.04 23.08 2.4 21.9 7
 
0.72
4000 3.62 27.36 2.9 25.9 0.72
5000 4.32 31.35 3.5 29.7 0.68
6300 5.25 35.06 4.2 33.3 8 0.68
8000 7.2 38.48 5.8 36.5 0.6
10000 8.7 45.32 7.0 43 0.6
12500 10.08 53.87 8.0 51.1 0.56
16000 12.16 65.84 9.7 62.5 0.54
20000 14.4 79.52 11.5 75.5 0.54
25000 17.02 94.05 13.6 89.6 10 0.45
31500 20.22 112.86 16.2 106.4 0.4
3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture3 Phase Power Transformer Electric Arc Furnace Distribution Step up Down Transformers Manufacture
1. Are you manufacturers ?
 We are a professional factory with 10 years experience in the field of High and low Voltage switch-gears,
Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.
2. Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters
3. What is your terms of payment ?
T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and pack-ages before you pay the balance.
4. Can your product be customerized ?
Considering differences in voltage. frequency and other speciality of transformer product in different countries and regions,our product can be customerized according to your requirements.
5. How do you solve quality problems?
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 1 days .

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier