Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
  • Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
Find Similar Products

Basic Info.

Model NO.
SCB
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Sinm
Warranty
2 Years
Use
Power
Material
Aluminum or Copper
Name
Electronic Power Transformer
Coil Number
Autotransformer
Type
Cast Resin Dry
Coil Structure
Toroidal
Product Name
Power Distribution Transformer
Trademark
sinm
Origin
Zhejiang, China
Production Capacity
5000pieces

Product Description

SCB series dry type transformers refer to transformers in which the core and windings are not immersed in insulating oil. The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When natural air cooling, the transformer can run continuously for a long time under the rated capacity. When forced air cooling, the output capacity of the transformer can be increased by 50% in short time. It is suitable for intermittent overload operation or emergency accident overload operation; due to the large increase in load loss and impedance voltage during overload, it is in an uneconomic operation state, so it should not be kept in continuous overload operation for a long time.

1.Power Capacity: 30-16000KVA

2.Voltage Level: 10KV,20KV,35KV or Others

3.Type of Voltage Regulation: Off-circuit or On-Ioad

4.Tapping Range: ±5 %  ±2x2.5 % ±4x2.5 %

5.Frequency: 50Hz or 60Hz

6.Phases: Three or Single

7.Connection Symbol: Dyn11,Yyn0 ( or as requested)

8.Short- circuit Impedance:  Standard Impedance

9.Maxmun Temperature Rise: 100K

10.Insulation Class:Class F or H

11.Protection Class:IP00/IP20/IP23/IP40/IP50

12.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.

 

Dry Type Power Transformer Features:
Since epoxy resin is a non-flammable, flame-retardant, self-extinguishing solid insulating material, safe and clean, epoxy resin cast dry-type transformers are oil-free, non-flammable, and have low operating loss, strong short-circuit resistance, less maintenance work, high working efficiency, small volume and low noise. It is often used in places with high performance requirements such as fire prevention and explosion protection, and has the following practical characteristics:
1.It is safe, fireproof, pollution-free, and can be directly operated in the load center;
2.High mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability and long service life;
3.Low loss, low noise, obvious energy saving effect, maintenance-free;
4.Good heat dissipation performance, and capacity operation can be increased in short time when forced air cooling;
5.Good moisture resistance;
6.Dry-type transformers can be equipped with a complete temperature detection and protection system. Using intelligent signal temperature control system, it can automatically detect and display the respective operating temperatures of the three-phase windings, can automatically start and stop the fan, and have functions such as alarms and trips. IS485 communication interface can be installed to realize wireless detection and intelligent management.
7.Small size, light weight, less space and low installation cost.

 

Dry Type Power Transformer Standard:
IEC60076, GB/T1094.11, GB/T17211.


Dry Type Power Transformer Applicable Environment:
1.0-40 (ºC), relative humidity <70%;
2.Altitude: no more than 2500 meters;
3.Avoid rain, humidity, high temperature, high heat or direct sunlight. 
4.Prevent working in places where there are more corrosive liquids, or gases, dust, conductive fibers or metal fines;
5.Prevent working in vibration or electromagnetic interference places;
6.Avoid long-term storage and transportation upside down, and avoid strong impact.
 

Dry Type Power Transformer Technical Parameter:

Model Rated capacity (KVA) Connection symbol Voltage combination (KV) No-load loss (W) Load loss (W) No-load current (%) Short circuit impedance (%)
High- Tapping range Low-
voltage voltage
SC(B)10-30 30 Yyn0 11 ±5% 0.4 190 710 2.4 4
SC(B)10-50 50 or 10.5 ±2×2.5% 270 1000 2.4
SC(B)10-80 80 Dyn11 10   370 1380 1.8
SC(B)10-100 100   6.3   400 1570 1.8
SC(B)10-125 125   6   470 1850 1.6
SC(B)10-160 160       550 2130 1.6
SC(B)10-200 200       630 2530 1.4
SC(B)10-250 250       720 2760 1.4
SC(B)10-315 315       880 3470 1.2
SC(B)10-400 400       980 3990 1.2
SC(B)10-500 500       1160 4880 1.2
SC(B)10-630 630       1350 5880 1
SC(B)10-630 630       1300 5960 1 6
SC(B)10-800 800       1520 6960 1
SC(B)10-1000 1000       1770 8130 1
SC(B)10-1250 1250       2090 9690 1
SC(B)10-1600 1600       2450 11730 1
SC(B)10-2000 2000       3050 14450 0.8
SC(B)10-2500 2500       3600 17170 0.8
SC(B)10-1600 1600       2450 12900 1 8
SC(B)10-2000 2000       3050 15890 0.8
SC(B)10-2500 2500       3600 18890 0.8

 

SCB12/13/14/18 10KV/0.4KV 100kVA-3150kVA

              High Voltage:10(6,6.3,10.5,11)KV                               Connection Symbol:D,yn11 or Y,yn0                           Rated Frequency:50Hz/60Hz
              Low Voltage:0.4(0.415,0.433)KV                                   Tapping Range of HV:±2x2.5%                                 Insulation Level:LI75 AC35/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
100 4 210 1120 245 1120 290 1240 1.5 45 590 1070 600 1160 1500 1100 2200
125 245 1320 290 1320 340 1460 1.3 46 740 1100 600 1200 1500 1100 2200
160 280 1510 330 1510 390 1680 1.3 46 810 1130 680 1240 1500 1100 2200
200 330 1800 380 1800 450 2000 1.1 46 890 1160 720 1250 1500 1100 2200
250 380 1960 445 1960 525 2180 1.1 46 1050 1220 720 1300 1500 1100 2200
315 465 2470 545 2470 640 2740 1.0 46 1250 1240 760 1260 1700 1300 2200
400 520 2840 605 2840 715 3150 1.0 46 1420 1260 830 1240 1700 1300 2200
500 610 3470 720 3470 845 3860 1.0 46 1530 1280 870 1200 1700 1350 2200
630 705 4180 830 4180 975 4650 0.9 48 1810 1330 880 1230 1700 1350 2200
630 6 680 4240 805 4240 945 4710 0.9 48 1760 1470 880 1180 1700 1350 2200
800 795 4950 940 4950 1105 5500 0.9 48 2090 1500 900 1130 1900 1350 2200
1000 930 5780 1095 5780 1290 6430 0.8 48 2500 1570 900 1220 1900 1350 2200
1250 1095 6890 1290 6890 1520 7660 0.8 48 2920 1610 900 1330 2100 1500 2200
1600 1290 8350 1515 8350 1780 9270 0.8 48 3650 1720 900 1420 2100 1500 2200
2000 1600 10280 1890 10280 2220 11420 0.7 50 4190 1780 980 1480 2300 1500 2200
2500 1890 12210 2230 12210 2620 13570 0.7 50 5400 2000 1020 1830 2300 1600 2200
3150 2340 14640 2695 14640 3100 16150 0.5 50 6730 2030 1270 2050 2350 1600 2200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 20KV/0.4KV 200kVA-3150kVA
                High Voltage::20(15,22,24)KV                                    Connection Symbol:D,yn11 or Y,yn0                                      Rated Frequency:50Hz/60Hz
                Low Voltage:0.4(0.415,0.433)KV                                  Tapping Range of HV:±2x2.5%                                           Insulation Level:LI125 AC55/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
200 6 390 2090 450 2090 530 2320 1.5 46 1250 1460 720 1350 1900 1350 2200
250 440 2430 520 2430 610 2700 1.3 46 1480 1490 720 1430 1900 1350 2200
315 510 2900 600 2900 710 3220 1.3 47 1550 1510 720 1470 2100 1400 2200
400 610 3450 710 3450 840 3820 1.1 48 1730 1550 720 1500 2100 1400 2200
500 710 4120 840 4120 980 4580 1.1 48 1980 1580 830 1550 2100 1400 2200
630 800 4870 950 4870 1110 5410 1.0 49 2280 1600 830 1600 2100 1500 2200
800 920 5870 1080 5870 1270 6530 1.0 50 3180 1730 830 1760 2300 1500 2200
1000 1080 6950 1280 6950 1500 7730 0.8 50 3580 1800 830 1780 2300 1500 2200
1250 1250 8180 1470 8180 1730 9090 0.8 52 3680 1820 900 1850 2400 1500 2200
1600 1460 9820 1720 9820 2030 10910 0.8 52 4680 1980 920 2040 2500 1600 2200
2000 1700 11600 2010 11600 2360 12880 0.7 53 5340 2200 960 2080 2700 1600 2200
2500 8 2030 13720 2400 13720 2810 15250 0.7 53 6480 2330 990 2170 2800 1700 2200
3150 2510 16330 2840 16330 3320 18150 0.6 54 7530 2360 1270 2250 2800 1700 2200
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.

SCB12/13/14/18 35KV/0.4KV 200kVA-3150kVA
              High Voltage: 35(33,38.5)KV                                 Connection Symbol:D,yn11 or Y,yn0                           Rated Frequency:50Hz/60Hz
              Low Voltage: 0.4(0.415,0.433)KV                         Tapping Range of HV:±2x2.5%                                   Insulation Level: LI200 AC85/AC3
Rated power
(KVA)
Short-Circuit Impedance(%) SC(B)18 (W) SC(B)14 (W) SC(B)12/13 (W) No-Load Current
(%)
Sound
pressure
dB(A)
Weight
(kg)
Inner Dimension(mm) Overall Dimension(mm)
No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC No-Load Loss On-Load Loss75ºC L W H L W H
200 6 470 2360 540 2360 640 2630 1.5 51 1550 1590 920 1790 2300 1600 2200
250 520 2700 610 2700 720 3010 1.3 51 1750 1590 920 1860 2300 1600 2200
315 620 3210 730 3210 850 3570 1.3 51 1950 1650 850 1750 2400 1700 2200
400 730 3850 850 3850 1000 4280 1.1 51 2200 1840 890 1800 2400 1700 2300
500 850 4730 1010 4730 1180 5260 1.1 52 2640 1910 920 1800 2500 1700 2300
630 970 5480 1150 5480 1350 6090 1.0 52 2880 1970 930 2100 2600 1700 2400
800 1130 5830 1340 5830 1570 6480 1.0 52 3530 1980 1030 2030 2600 1800 2500
1000 1280 7400 1510 7400 1760 8230 0.8 52 4080 2070 1060 2070 2700 1800 2500
1250 1480 9040 1750 9040 2060 10040 0.8 53 4430 2080 1050 2080 2700 1800 2500
1600 1710 10960 2010 10960 2360 12180 0.8 53 5310 2150 1050 2180 2800 1800 2600
2000 2010 12960 2370 12960 2780 14390 0.7 54 6410 2300 1050 2250 2900 1800 2700
2500 8 2340 15500 2760 15500 3240 17230 0.7 55 7630 2400 1100 2230 3000 2000 2700
3150 2890 18590 3330 18590 3830 20510 0.6 55 7530 2500 1200 2350 3000 2000 2800
Note: The above parameters are only for designing and selecting  reference, and the final parameters are subject to the actual product.
Basic structure of dry-type transformer
1. Iron core: stacked by silicon steel sheet, is the magnetic circuit part of the transformer, used to guide the magnetic flux.
2. Winding: divided into high-voltage winding and low-voltage winding, respectively wound on the iron core, used to realize the conversion and transmission of electric energy.
3. Insulating cylinder: placed between high and low voltage coils, used to increase electrical insulation and ensure the safe operation of the transformer.
4. pads: used to support and restrain the coils to maintain their stability and shape.
5. Fasteners: used to connect and fix each part of the transformer, with anti-loosening performance.
Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
 
 
Superior Quality Dry Type Transformer Price Various kVA Safety Dry-Type TransformerSuperior Quality Dry Type Transformer Price Various kVA Safety Dry-Type TransformerSuperior Quality Dry Type Transformer Price Various kVA Safety Dry-Type TransformerSuperior Quality Dry Type Transformer Price Various kVA Safety Dry-Type TransformerSuperior Quality Dry Type Transformer Price Various kVA Safety Dry-Type TransformerSuperior Quality Dry Type Transformer Price Various kVA Safety Dry-Type Transformer
1. Are you manufacturers ?
 We are a professional factory with 10 years experience in the field of High and low Voltage switch-gears,
Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.
2. Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters
3. What is your terms of payment ?
T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and pack-ages before you pay the balance.
4. Can your product be customerized ?
Considering differences in voltage. frequency and other speciality of transformer product in different countries and regions,our product can be customerized according to your requirements.
5. How do you solve quality problems?
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 1 days .
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier