  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
  • Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
Find Similar Products
  • Overview
  • Product Description
  • Fields of application
  • After Sales Service
Overview

Basic Info.

Model NO.
CK(BK/XK/LK)GKL
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Shape of Core
Ring
Brand
Sinm
Trademark
Sinm
Origin
China
Production Capacity
5000pieces

Product Description

Product Description

The current limiting reactor is connected in series with the power system to limit the short-circuit current when the  power system fails. When the line is short-circuited,  the current-limiting reactor uses its reactor characteristics to limit the short-circuit current of the line within a  certain limit,  so that the switchgear can remove the fault smoothly and effectively. Current-limiting reactors generally use air-core  reactors with better linearity of reactance value.
The current-limiting reactor can operate safely and reliably under  long-term rated current. In case of failure, its ampere-turns increase several times or dozens of times,  but its resistance or ability to limit short-circuit current cannot be reduced. Therefore,  the current limiting reactor should be made of hollow products instead of iron core products. The air-core reactor is an  inductive high-voltage electrical appliance used in the power system to limit short-circuit current,  reactive power compensation and equal shifting. The magnetic flux forms a loop through the air,  so it is called an air-core reactor. If the rated voltage and supply voltage of squirrel-cage AC three-phase  asynchronous motor are the same,  an air-core reactor with the same number of turns as the motor can be connected in series between the motor and the  incoming power supply to increase the inductance value and control the starting current not to be too high.
Hollow  reactors are mainly divided into hollow series reactors, hollow filter reactors, hollow shunt reactors, hollow current limiting reactors, hollow split reactors, hollow starting reactors, etc.,  which are often used for reactive power compensation, harmonic filtering, current limiting and other occasions.

zDry-Type Air-Core Current-Limiting Reactor 10kv 35kv
Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv


Ordering Information
           Nominal system voltage
           Rated continuous current
           Rated reactance rate
          Rated reactance
          Rated short-time current
          Mode of installation (horizontal or vertical)
          Working environment (indoors or outdoors)
          Angle between inlet and outlet
         Other special requirement
Product Standard

GB/T 1094.6-2011     IEC 60076-6:2007
GB/T 1094.1-2011     IEC 60076-1:2011
GB/T 1094.3-2017     IEC 60076-3:2013
Detailed Photos
Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
 

Dry-type air-core current-limiting reactor 10kV
 

 Part No.

Rated current
A


Rated
reactance rate


Rated reactance
Ω


Short-
 time
current
kA


Single- phase
power
kvar


Single- phase loss75C
kW

Overall dimension


Pitch diameter
Dc
mm


Weight
(per
phase)
 kg



Suggested arrangement mode
Ds
mm
H
mm
XKGKL-10-800-5 800 5% 0.361 16.00 230.9 4.6 1270 770 1170 350
side by side
XKGKL-10-800-8 8% 0.577 10.00 369.5 5.7 1380 840 1280 420
XKGKL-10-800-10 10% 0.722 8.00 461.9 6.5 1480 890 1380 490
XKGKL-10-800-12 12% 0.866 6.67 554.3 7.7 1530 940 1430 547
XKGKL-10-1000-5 1000 5% 0.289 20.00 288.7 6.0 1330 710 1240 370
XKGKL-10-1000-8 8% 0.462 12.50 461.9 7.2 1480 820 1380 530
XKGKL-10-1000-10 10% 0.577 10.00 577.4 8.7 1670 760 1480 580
XKGKL-10-1000-12 12% 0.693 8.33 692.8 9.8 1670 820 1480 630
XKGKL-10-1500-5 1500 5% 0.192 30.00 433.0 8.1 1380 730 1200 477
XKGKL-10-1500 8 8% 0.308 18.75 692.8 9.4 1590 780 1320 662
XKGKL-10-1500-10 10% 0.385 15.00 866.1 11.3 1590 850 1330 718
XKGKL-10-1500-12 12% 0.462 12.50 1039.3 12.8 1700 880 1430 857
XKGKIA0-2000/5 2000 5% 0.144 40.00 577.4 9.1 1710 600 1580 544
XKGKL-10-2000-8 8% 0.231 25.00 923.8 11.6 1770 700 1590 746
XKGKL-10-2000-10 10% 0.289 20.00 1154.7 13.5 1870 730 1680 778
XKGKL-10-2000-12 12% 0.346 16.67 1385.7 14.9 1860 800 1680 1000
XKGKL-10-2500-5 2500 5% 0.115 50.00 721.7 10.2 1544 790 1280 678
XKGKL-10-2500-8 8% 0.185 31.25 1154.7 13.7 1600 960 1330 946
XKGKL-10-2500-10 10% 0.231 25.00 1443.4 15.3 1740 980 1480 1085
XKGKL-10-2500-12 12% 0.277 20.83 1732.1 18.1 1730 1000 1460 1200
XKGKL-10-3000-5 3000 5% 0.096 60.00 866.0 11.2 1620 830 1440 733
XKGKL-10-3000-8 8% 0.154 37.50 1386.0 15.1 1720 930 1540 975
XKGKL-10-3000-10 10% 0.192 30.00 1732.0 17.5 1750 1130 1650 1103
XKGKL-10-3000-12 12% 0.231 25.00 2079.0 19.1 1760 1030 1500 1253
XKGKL-10-3500-5 3500 5% 0.082 70.00 1010.0 12.7 1700 800 1440 980
XKGKL-10-3500-8 8% 0.132 43.75 1617.0 15.7 1820 880 1710 1322
XKGKL-10-3500-10 10% 0.165 35.00 2021.0 18.9 1820 950 1710 1500
XKGKL-10-3500-12 12% 0.198 29.17 2425.0 20.1 1820 1020 1710 1700
XKGKL-10-4000-5 4000 5% 0.072 80.00 1155.0 12.1 1750 800 1640 1058
XKGKL-10-4000 8 8% 0.115 50.00 1848.0 17.8 1880 880 1700 1461
XKGKL-10-4000-10 10% 0.144 40.00 2309.0 20.7 1970 880 1700 1687
XKGKL-10-4000-12 12% 0.173 33.33 2771.0 22.6 2010 930 1740 1833


35kV series
  
Part No.


Rated current
A


Rated
reactance rate


Rated reactance
Ω


Short-
 time
current
kA


Single- phase
power
kvar


Single- phase loss75C
kW

Overall dimension


Pitch diameter
Dc
mm


Weight
(per
phase)
 kg



Suggested arrangement mode
Ds
mm
H
mm
XKGKL-35-200-4 200 4% 4.042 5.00 161 3.8 1590 600 1130 340
side by side
XKGKL-35-200-5 5% 5.052 4.00 202 4.7 1640 630 1180 410
XKGKL-35-200-6 6% 6.062 3.33 242 5.2 1700 630 1180 480
XKGKL-35-200-8 8% 8.083 2.50 323 6.3 1760 650 1570 560
XKGKL-35-400-5 400 5% 2.256 8.00 404 6.7 1780 730 1330 670
XKGKL-35-400 8 8% 4.042 5.00 646 8.4 1700 690 1510 880
XKGKL-35-400-10 10% 5.052 4.00 808 9.6 2000 680 1810 970
XKGKL-35-400 12 12% 6.062 3.33 970 10.7 2000 730 1810 1050
XKGKL-35-600-5 600 5% 1.684 12.00 606 8.2 1680 650 1550 850
XKGKL-35-600-8 8% 2.694 7.50 970 10.5 1980 700 1790 1120
XKGKL-35-600-10 10% 3.368 6.00 1212 12.9 1980 780 1790 1340
XKGKL-35-600-12 12% 4.042 5.00 1454 13.8 2030 800 1840 1520
XKGKL-35-800-5 800 5% 1.263 16.00 808 9.4 1800 650 1600 980
XKGKL-35-800-8 8% 2.021 10.00 1293 13.3 2100 650 1920 1420
XKGKL-35-800-10 10% 2.526 8.00 1616 14.9 2100 830 1920 1650
XKGKL-35-800-12 12% 3.031 6.67 1939 16.5 2100 760 1920 1720
XKGKL-35-1000-5 1000 5% 1.010 20.00 1010 10.2 1670 700 1540 1270
XKGKL-35-1000 8 8% 1.617 12.50 1616 14.2 1870 800 1680 1620
XKGKL-35-1000-10 10% 2.021 10.00 2020 16.9 1940 800 1750 1740
XKGKL-35-1000 12 12% 2.425 8.33 2424 18.6 2070 880 1880 1870
XKGKL-35-1500-5 1500 5% 0.674 30.00 1515 13.8 1700 750 1510 1550
XKGKL-35-1500-8 8% 1.078 18.75 2424 17.9 1820 800 1620 1910
XKGKL-35-1500-10 10% 1.347 15.00 3031 20.7 1800 900 1600 2200
XKGKL-35-1500-12 12% 1.617 12.50 3637 23.2 2300 900 2110 2380
Fields of application

The reactor is mainly used in the power system, to adjust the reactive power distribution in the system, reduce the power frequency voltage, and suppress the harmonic current and flicker. The following are some common applications: 

 1. In the power system: The reactor plays the role of regulating the reactive power in the power system, which can improve the stability of the system. For example, installing a parallel reactor in a transmission line can balance the reactive power and reduce line loss; installing a series reactor in a transformer can reduce the no-load current and extend the life of the equipment. 
  
 2. In the motor system: the reactor can be used during the starting and braking of the motor to reduce the starting current and the impact current during the braking process. In addition, it can also be used to prevent the self-excited magnetic phenomenon of the motor under light or no-load. 
  
 3. In electronic equipment and communication systems: reactors can be used to suppress the high-order harmonic components in the power supply and reduce the impact on electronic equipment. For example, high-frequency reactors are used in switching power supplies, inverters, communication equipment, etc.
Dry-Type Air-Core Current-Limiting Reactor 10kv 35kv
 
After Sales Service

1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.

2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.

3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier