630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer

Product Details
Customization: Available
Application: Power, Electronic, Instrument, Lighting, Rectifier, Audio
Phase: Three
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
to see all verified strength labels (20)
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
  • 630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
Find Similar Products

Basic Info.

Model NO.
SCB
Core
Core-type Transformer
Cooling Method
Dry-type Transformer
Winding Type
Two-winding Transformer
Certification
ISO9001-2000, ISO9001
Usage
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Frequency Characteristics
Power Frequency
Shape of Core
Ring
Brand
Sinm
Warranty
2 Years
Use
Power
Material
Aluminum or Copper
Name
Electronic Power Transformer
Coil Number
Autotransformer
Type
Cast Resin Dry
Coil Structure
Toroidal
Product Name
Power Distribution Transformer
Frequency
50
Trademark
sinm
Origin
Zhejiang, China
Production Capacity
5000pieces

Product Description

SCB series dry type transformers refer to transformers in which the core and windings are not immersed in insulating oil. The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When natural air cooling, the transformer can run continuously for a long time under the rated capacity. When forced air cooling, the output capacity of the transformer can be increased by 50% in short time. It is suitable for intermittent overload operation or emergency accident overload operation; due to the large increase in load loss and impedance voltage during overload, it is in an uneconomic operation state, so it should not be kept in continuous overload operation for a long time.

1.Power Capacity: 30-16000KVA

2.Voltage Level: 10KV,20KV,35KV or Others

3.Type of Voltage Regulation: Off-circuit or On-Ioad

4.Tapping Range: ±5 %  ±2x2.5 % ±4x2.5 %

5.Frequency: 50Hz or 60Hz

6.Phases: Three or Single

7.Connection Symbol: Dyn11,Yyn0 ( or as requested)

8.Short- circuit Impedance:  Standard Impedance

9.Maxmun Temperature Rise: 100K

10.Insulation Class:Class F or H

11.Protection Class:IP00/IP20/IP23/IP40/IP50

12.Altiude is not exceeding 1000m,ambient temperature not exceeding 40OC. If it can't meet such conditions,we will modulate parameters in accordance with standard.

 

Dry Type Power Transformer Features:
Since epoxy resin is a non-flammable, flame-retardant, self-extinguishing solid insulating material, safe and clean, epoxy resin cast dry-type transformers are oil-free, non-flammable, and have low operating loss, strong short-circuit resistance, less maintenance work, high working efficiency, small volume and low noise. It is often used in places with high performance requirements such as fire prevention and explosion protection, and has the following practical characteristics:
1.It is safe, fireproof, pollution-free, and can be directly operated in the load center;
2.High mechanical strength, strong short-circuit resistance, small partial discharge, good thermal stability, high reliability and long service life;
3.Low loss, low noise, obvious energy saving effect, maintenance-free;
4.Good heat dissipation performance, and capacity operation can be increased in short time when forced air cooling;
5.Good moisture resistance;
6.Dry-type transformers can be equipped with a complete temperature detection and protection system. Using intelligent signal temperature control system, it can automatically detect and display the respective operating temperatures of the three-phase windings, can automatically start and stop the fan, and have functions such as alarms and trips. IS485 communication interface can be installed to realize wireless detection and intelligent management.
7.Small size, light weight, less space and low installation cost.

 

Dry Type Power Transformer Standard:
IEC60076, GB/T1094.11, GB/T17211.


Dry Type Power Transformer Applicable Environment:
1.0-40 (ºC), relative humidity <70%;
2.Altitude: no more than 2500 meters;
3.Avoid rain, humidity, high temperature, high heat or direct sunlight. 
4.Prevent working in places where there are more corrosive liquids, or gases, dust, conductive fibers or metal fines;
5.Prevent working in vibration or electromagnetic interference places;
6.Avoid long-term storage and transportation upside down, and avoid strong impact.
 

Dry Type Power Transformer Technical Parameter:

Model Rated capacity (KVA) Connection symbol Voltage combination (KV) No-load loss (W) Load loss (W) No-load current (%) Short circuit impedance (%)
High- Tapping range Low-
voltage voltage
SC(B)10-30 30 Yyn0 11 ±5% 0.4 190 710 2.4 4
SC(B)10-50 50 or 10.5 ±2×2.5% 270 1000 2.4
SC(B)10-80 80 Dyn11 10   370 1380 1.8
SC(B)10-100 100   6.3   400 1570 1.8
SC(B)10-125 125   6   470 1850 1.6
SC(B)10-160 160       550 2130 1.6
SC(B)10-200 200       630 2530 1.4
SC(B)10-250 250       720 2760 1.4
SC(B)10-315 315       880 3470 1.2
SC(B)10-400 400       980 3990 1.2
SC(B)10-500 500       1160 4880 1.2
SC(B)10-630 630       1350 5880 1
SC(B)10-630 630       1300 5960 1 6
SC(B)10-800 800       1520 6960 1
SC(B)10-1000 1000       1770 8130 1
SC(B)10-1250 1250       2090 9690 1
SC(B)10-1600 1600       2450 11730 1
SC(B)10-2000 2000       3050 14450 0.8
SC(B)10-2500 2500       3600 17170 0.8
SC(B)10-1600 1600       2450 12900 1 8
SC(B)10-2000 2000       3050 15890 0.8
SC(B)10-2500 2500       3600 18890 0.8
Basic structure of dry-type transformer
1. Iron core: stacked by silicon steel sheet, is the magnetic circuit part of the transformer, used to guide the magnetic flux.
2. Winding: divided into high-voltage winding and low-voltage winding, respectively wound on the iron core, used to realize the conversion and transmission of electric energy.
3. Insulating cylinder: placed between high and low voltage coils, used to increase electrical insulation and ensure the safe operation of the transformer.
4. pads: used to support and restrain the coils to maintain their stability and shape.
5. Fasteners: used to connect and fix each part of the transformer, with anti-loosening performance.
630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
 
 
630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer630 800 kVA Three Phase Dry Type Current Power Distribution Electrical Transformer
1. Are you manufacturers ?
 We are a professional factory with 10 years experience in the field of High and low Voltage switch-gears,
Substation,transformers,cable distribution box and various electrical equipment, such as vacuum circuit breaker , load break switch etc.
2. Do you accept customized serveice ?
We offer OEM/ODM service , can print your logo on product . our professional technical and quotation team can provice a satisfied project according to your drawing and parameters
3. What is your terms of payment ?
T/T 30% as deposit, and 70% before delivery. We'll show you the photos of the products and pack-ages before you pay the balance.
4. Can your product be customerized ?
Considering differences in voltage. frequency and other speciality of transformer product in different countries and regions,our product can be customerized according to your requirements.
5. How do you solve quality problems?
Please porvide detailed photoes of quality problems. our technical and quality testing department will analyse.we will make asatisfied soluton within 1 days .
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier